There are a total of 144 constant current outputs.
Set working parameters, interlock protection values, alarm values, calibrate PD, etc. through the upper computer; Can record running time, store fault record analysis, and upload;
CAN communication remote control mode;
The current output has a gradual rise and fall function, without overshoot or kickback;
Output current ripple: ± 0.5%; Current stability: ± 0.5%; Current rising edge less than 10us;<; p="">
Overtemperature and overcurrent hardware and software interlock protection, PD hardware interlock protection;
25 channels of PD, 7 channels of temperature, and 1 channel of flow switch detection;
The delay between the first, second, and third level amplification channels can be adjusted;
Comes with indicator light drive and control.
144 independent constant current outputs, supporting three-level amplification delay adjustment, meeting the integration requirements of industrial grade multi-channel laser systems.
25 channel PD+multi environmental sensor detection, dual overcurrent/overtemperature protection, built-in indicator light drive, ensuring high reliability of the system.
CAN communication remote control+upper computer parameter configuration, real-time recording of operating data, gradual rise and fall of current without impact, ripple ± 0.5%.
| Specifications | Parameter |
|---|---|
| Input voltage range | AC340-440V, 50/60Hz, 3-phase |
| LD modules | Route 144 |
| Output parameters |
6 * (Level 1: 14V 0-15A constant current 1 channel, Level 2: 22V 0-15A constant current 1 channel, Level 3: 50V 0-30A constant current 22 channels |
| Channel delay | 1-1000ms |
| Current quality | Current ripple: ± 0.5%; Current stability: ± 0.5%; |
| Total power | ≥190KW |
| Efficiency | >90% |
| Control |
Communication method: Ethernet Control software: main control, detection, backend operation, remote simulation |
| Temperature | Temperature:-25-60℃; StorageTemperature:-40-85℃ |
| Humidity | Work:20-90%RH, Non condensing Storage: 10-95% RH, non condensing |
| Insulation | Voltage Resistance: 1500Vac 10mA 60S, Insulation Resistance ≥ 20M Ω |
| Cooling | water cooling |

Warranty: 360 days
▶ The warranty period for power products is 12 months, calculated from the date of purchase.
▶ During the warranty period, faults that are not caused by human factors can be repaired free of charge; Malfunctions caused by human damage or excessive use require paid repairs.
▶ Before using this power supply, please read the manual carefully. We are not responsible for any damage or problems caused by improper use or failure to follow the manual
Submit this form and we will contact you soon