Built in energy storage capacitor, reducing external installation leads;
Built in control circuit, can be controlled using standard Mod bus protocol;
Combined with the light energy detection unit, real-time feedback of light energy can be achieved;
Internal modular design to prevent crosstalk and reduce RE electromagnetic radiation;
Medical beauty power supply comes standard with a protective casing, which is radiation resistant, anti bounce, and has a stable installation structure;
The whole machine is designed in accordance with the YY0505-2012 and IEC60601-1-2 standards for medical electrical equipment.
Built in Mod bus protocol control circuit, combined with real-time light energy feedback system, achieves precise adjustment of treatment parameters.
Modular structure+radiation resistant casing effectively reduces electromagnetic interference, and anti bounce design ensures stable operation of the equipment.
Compliant with YY0505/IEC60601 international medical standards, with built-in energy storage capacitors for simplified installation, ensuring safe and reliable treatment.
| Specifications | Parameter |
|---|---|
| Input Voltage | AC220V±15%,47-63Hz |
| Leakage Current | < 0.4mA/250VAC |
| Output Power | 2000W |
| Maximum output energy of pulse (under the condition of a capacitance of 2000uF) | 232J |
| Output Frequency | 1-50Hz adjustable |
| Output Mode | Pulse group ①, single pulse ② |
| Discharge Pulse Width | 50μs-950μS |
| Output Pulse Energy Imbalance | < 2% |
| Control Signal | External analog, LCD screen, Mod bus protocol |
| Protect | Output overvoltage protection, overcurrent protection, and no-load protection |
| Temperature | Work:-15℃~45℃ Storage:-40℃~85℃ |
| Humidity | No frost or condensation |
| Safety regulations and electromagnetic compatibility | Designed in accordance with YY0505-2012 and IEC6061-1-2 standards for medical electrical equipment |
| Cooling Method | forced air cooling |
| Weight(KG) | 6 |
| Dimensions(mm) | 282*148*197 |
Warranty: 360 days
▶ The warranty period for power products is 12 months, calculated from the date of purchase.
▶ During the warranty period, faults that are not caused by human factors can be repaired free of charge; Malfunctions caused by human damage or excessive use require paid repairs.
▶ Before using this power supply, please read the manual carefully. We are not responsible for any damage or problems caused by improper use or failure to follow the manual
Submit this form and we will contact you soon